10/02/2017 09:09:31
Module - HVAC - High Voltage Controller
Correction code 18010402
Remove
- Remove condenser rear exit duct (refer to procedure).
-
Disconnect HVAC high voltage controller connectors (x4).
- Remove Patchbolts (x4) securing module to body (torque 15 Nm).
- Remove nut securing ground lead to module (torque 10 Nm).
-
Remove bolt securing A/C low pressure charge port P-clip to bracket (torque 12 Nm).
- Remove Patchbolts (x2) securing module rear mounting bracket to body (torque 15 Nm).
- Release fan harness clip from bracket.
-
Lift and rotate module to view hood switch connectors. Disconnect hood switch connector and remove module.
- Remove nuts (x4) securing rear mounting bracket to module and remove bracket (torque 12 Nm).
- Remove front mounting brackets and rubber mountings (x2) from module.
Install
Installation procedure is the reverse of removal, except for the following:
CAUTION
Connectors should only be tightened by hand.
CAUTION
Replace all patchbolts.