Module - HVAC - High Voltage Controller

Correction code 18010402

Remove

  1. Remove condenser rear exit duct (refer to procedure).
  2. Disconnect HVAC high voltage controller connectors (x4).
  3. Remove Patchbolts (x4) securing module to body (torque 15 Nm).
  4. Remove nut securing ground lead to module (torque 10 Nm).
  5. Remove bolt securing A/C low pressure charge port P-clip to bracket (torque 12 Nm).
  6. Remove Patchbolts (x2) securing module rear mounting bracket to body (torque 15 Nm).
  7. Release fan harness clip from bracket.
  8. Lift and rotate module to view hood switch connectors. Disconnect hood switch connector and remove module.
  9. Remove nuts (x4) securing rear mounting bracket to module and remove bracket (torque 12 Nm).
  10. Remove front mounting brackets and rubber mountings (x2) from module.

Install

Installation procedure is the reverse of removal, except for the following:

Warning IconA warning icon, calling your attention to a possibly risky situation
CAUTION
Connectors should only be tightened by hand.
Warning IconA warning icon, calling your attention to a possibly risky situation
CAUTION

Replace all patchbolts.