2025-10-24
Insulator - Fast Charge Access - Ancillary Bay (Model YL) (Remove and Replace)
Correction code
16300500302
FRT
1.98
NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so.
NOTE: See Flat Rate Times to learn more about FRTs and how they are created.
NOTE: See Personal Protection to make sure you
are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Patch bolt that attaches the negative/positive fast charge busbar to the DC link side. |
![]() 5 Nm (3.7 lbs-ft) + 60 degrees |
|
Replace | 1104475-00-F |
| Bolts (x2) that attach the fast charge contactor assembly to the ancillary bay |
![]() 5.5 Nm (4.1 lbs-ft) |
|
Reuse |
Remove
- Remove the left terminals cover. See Cover - Left Terminals - Ancillary Bay (Model YL) (Remove and Replace).
-
Disconnect the AC filter harness connector from the PCS2 Lite by pulling the locking
tab upward.
-
Disconnect the LV fast charge contactor connector by pressing the tabs on both sides
with your hands and pulling the connector upwards.
-
Disconnect the AC filter harness connectors (x2) from the fast charge contactor cover
by releasing the locking tabs and pulling them off.
-
Remove the harness clips (x3) from the fast charge contactor cover and move the
wiring harness aside.
-
Remove and discard the patch bolt that attaches the negative fast charge busbar to
the DC link side.
TIpUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 13MM, HV INSULATED
-
Remove and discard the patch bolt that attaches the positive fast charge busbar to
the DC link side.
TIpUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 13MM, HV INSULATED
- Remove the HV input header seal. See Seal - HV Input Header (Model YL) (Remove and Replace).
-
Remove the bolts (x2) that attach the fast charge contactor assembly to the ancillary
bay.
TIpUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 10MM, UNIV, HV INSULATED
-
Remove the fast charge contactor assembly from the ancillary bay by releasing the
clip, disengaging the guide pins (x2), and tilting it upwards.
- Remove the HV insulating gloves and leather over gloves.
-
Remove the fast charge access insulator from the fast charge contactor assembly by
releasing the clips (x7), disengaging the alignment pin, and tilting the harness clip
upwards to remove it.
Replace
-
Install the fast charge access insulator to the fast charge contactor assembly by
aligning the alignment pin, securing the clips (x7) and the harness clip.
NoteEnsure that all clips are installed in place.
- Put on the HV insulating gloves and leather over gloves.
-
Install the fast charge contactor assembly to the ancillary bay by tilting it at a
certain angle, aligning the guide pins (x2), and securing the clip.
-
Install the bolts (x2) that attach the fast charge contactor assembly to the
ancillary bay.
5.5 Nm (4.1 lbs-ft)NoteMark the bolts after torque.TIpUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 10MM, UNIV, HV INSULATED
- Install the HV input header seal. See Seal - HV Input Header (Model YL) (Remove and Replace).
-
Install a new patch bolt that attaches the positive fast charge busbar to the DC link
side.
5 Nm (3.7 lbs-ft) + 60 degreesNoteMark the bolt after torque.TIpUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 13MM, HV INSULATED
-
Perform a Hioki impedance test on the positive HV joint ensuring it is 25𝜇Ω or
less.
-
Install a new patch bolt that attaches the negative fast charge busbar to the DC link
side.
5 Nm (3.7 lbs-ft) + 60 degreesNoteMark the bolt after torque.TIpUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 13MM, HV INSULATED
-
Perform a Hioki impedance test on the negative HV joint ensuring it is 40𝜇Ω or
less.
-
Secure the harness clips (x3) to the fast charge contactor cover.
-
Connect the AC filter harness connectors (x2) to the fast charge contactor
cover
-
Connect the LV fast charge contactor connector.
-
Connect the AC filter harness connector to the PCS2 Lite by pushing it downward, then
pushing the locking tab downward to secure it.
NoteEnsure the connector is fully seated.
- Install the left terminals cover. See Cover - Left Terminals - Ancillary Bay (Model YL) (Remove and Replace).