2026-02-10
Busbar - Fast Charge - Input - Negative (Model Y L) (Remove and Replace)
Correction code 16300502302 FRT 1.98 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See Personal Protection to make sure you are wearing proper PPE when performing the procedure below. NOTE: See Ergonomic Precautions for safe and healthy working practices.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Patch bolt that attaches the negative/positive input fast charge busbar to the fast charge contactor |
![]() 10 Nm (7.4 lbs-ft) - 180 degrees |
|
Replace | 1104475-00-F Note Tighten the bolt to 10 Nm, back off 180 degrees, then torque to 10 Nm. |
Remove
- Remove the fast charge access insulator. See Insulator - Fast Charge Access - Ancillary Bay (Model YL) (Remove and Replace).
-
Remove the fast charge HV carrier from
the fast charge contactor assembly by releasing the tabs (x6).
-
Release the location pins (x3) and
tabs (x2), then remove and discard the patch bolt that attaches the negative input fast
charge busbar to the fast charge contactor.
TIpUse of the following tool(s) is recommended:
- SKT, 1/4" SQ DR, 13MM, HV INSULATED
Replace
-
Secure the location pins (x3) and tabs
(x2), then install a new patch bolt that attaches the negative input fast charge busbar
to the fast charge contactor.
10 Nm (7.4 lbs-ft) - 180 degreesNoteTighten the bolt to 10 Nm, back off 180 degrees, then torque to 10 Nm.NoteMark the bolt after torque.TIpUse of the following tool(s) is recommended:- SKT, 1/4" SQ DR, 13MM, HV INSULATED
-
Install the fast charge HV carrier to
the fast charge contactor assembly, ensuring all the tabs (x6) are secured.
- Install the fast charge access insulator. See Insulator - Fast Charge Access - Ancillary Bay (Model YL) (Remove and Replace).