2024-10-17

Event Data Recorder Retrieval

  • 2024-10-07: Added OBD2 connection EDR data retrieval section.
Warning IconA warning icon, calling your attention to a possibly risky situation
ADVARSEL
Denne prosedyren er et UTKAST. Selv om den har blitt godkjent, kan det hende at advarsler og forholdsregler mangler. Følg sikkerhetskravene, og vær ytterst forsiktig ved arbeid på eller nær høyspenningssystemer og -komponenter. Send korrigeringer og tilbakemeldinger til ServiceDevelopment@teslamotors.com.
Informational PurposesAn informational icon, calling your attention
Merk
Refer to CD-20-20-001 for Model Y Event Data Recorder (EDR) guide.
Informational PurposesAn informational icon, calling your attention

Establish a Direct-to-Module Connection (Non-Structural Pack)

  1. Open all of the doors.
  2. Lower all of the windows.
  3. On the vehicle touchscreen, select the Tesla symbol, and then confirm and note the vehicle’s firmware version.
    Figur 1. Model 3 shown; Model Y similar
  4. Remove the Restraint Control Module (RCM). See Modul – Restraint Control (Uten strukturell pakke) (fjerne og skifte ut).
  5. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Bruk av følgende verktøy anbefales:
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  6. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Bruk av følgende verktøy anbefales:
    • PCAN USB to CAN adapter - 1016990-00-A
  7. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  8. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  9. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Merk
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  10. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  11. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    Merk
    EDR retrieval time will vary based on the user and retrieved data.
  12. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  13. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  14. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  15. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  16. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  17. Install the RCM. See Modul – Restraint Control (Uten strukturell pakke) (fjerne og skifte ut).
  18. Raise all of the windows.
  19. Close all of the doors.

Establish a Direct-to-Module Connection (Structural Pack)

  1. Remove the RCM. See Modul – Restraint Control (strukturell pakke) (fjerne og skifte ut).
  2. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Bruk av følgende verktøy anbefales:
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  3. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Bruk av følgende verktøy anbefales:
    • PCAN USB to CAN adapter - 1016990-00-A
  4. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  5. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  6. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Merk
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  7. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  8. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    Merk
    EDR retrieval time will vary based on the user and retrieved data.
  9. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  10. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  11. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  12. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  13. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  14. Install the RCM. See Modul – Restraint Control (strukturell pakke) (fjerne og skifte ut).

Establish an In-Vehicle Connection (OBD2 Port)

  1. Open the LH front door.
  2. Lower the LH front window.
  3. Connect the OBD2 diagnostics cable to the PCAN-USB adapter.
    Informational PurposesAn informational icon, calling your attention
    Merk
    Bruk av følgende verktøy anbefales:
    • OBD2 Diagnostics Cable - 2077826-00-A
    • PCAN-USB Adapter - 1016990-00-A
  4. Connect the OBD2 diagnostics cable to the vehicle's OBD2 port.
  5. Connect the PCAN-USB adapter to the laptop USB port.
  6. Open the Tesla EDR Retrieval Program. The program automatically attempts to connect to the RCM.
    Informational PurposesAn informational icon, calling your attention
    Merk
    When connected properly, a green circle and the message “Connected to RCM” displays on the bottom left corner of the window.
  7. Once connected to the EDR, click “Run EDR Retrieval” and follow the on-screen prompts to retrieve and save EDR data.
  8. The retrieved *.edr data file can be used to generate a Tesla EDR Report at https://edr.tesla.com.
  9. Close the Tesla EDR Retrieval Program.
  10. Disconnect the PCAN-USB adapter from the laptop USB port.
  11. Disconnect the OBD2 diagnostics cable from the vehicle's OBD2 port.
  12. Disconnect the OBD2 diagnostics cable from the PCAN-USB adapter.
  13. Raise the LH front window.
  14. Close the LH front door.