烟火电池断接开关(拆卸和更换)

校正代码 16300002 1.13 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and its associated FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See 人员保护 to make sure wearing proper PPE when performing the below procedure. NOTE: See 人体工程学注意事项 for safe and healthy working practices.

  • 2026-08-05: 删除了记录替换用烟火电池断接开关序列号和零件号(以便稍后输入到 SCA 中)的步骤。
  • 2026-04-09: 更新了紧固过程和规格值。
  • 2024 年 10 月 7 日:更新了第 7 步的图片,以展示适当的个人防护装备 (PPE)。
  • 2024 年 1 月 31 日:添加了操作 Hioki 电阻测试步骤相关零件的真实图片。
  • 2023 年 7 月 25 日:添加了记录替换用烟火电池断接开关序列号和零件号(以便稍后输入到 SCA 中)的步骤。
  • 2023 年 6 月 29 日:在“安装”部分的第 5 步添加了一个视频。
警告
Supplemental Restraint System (SRS) components can be hazardous if not serviced and handled correctly. See
警告
In the event of an airbag or seatbelt pretensioner deployment, certain components must be replaced, and other components must be inspected for damage. Refer to the Collision Repair Manual for a specific list of items that must be inspected and replaced.
设备:
  • 1057602-00-A Ratchet, 1/4" Sq Dr, HV Insulated
  • 1057603-00-A Ext Bar, Wobble, 1/4" Dr, HV Insulated
  • 1057606-00-A 1/4" 高压绝缘套筒 13mm
  • 1057607-00-A Magnet, Flexible, HV Insulated, 18"
  • 1127845-00-A 高压电池仓维修盖板总成,Model 3
  • 1131071-00-A 烟火断接虚拟安全开关
  • 1133602-00-A Kit, HV Pyro-disconnect Replacement, BRP
  • 1108272-00-B 变流器逻辑连接器盖,3DU
  • 1076927-00-A 微欧电阻计,Hioki RM 3548
警告
Remove all jewelry (watches, bracelets, rings, necklaces, earrings, ID tags, piercings, etc.) from your person, and all objects (keys, coins, pens, pencils, tools, fasteners, etc.) from your pockets before performing any procedure that exposes you to high voltage.
警告
If corrective eyewear is necessary to safely perform any procedure, make sure that the eyewear is securely restrained to the head and cannot fall off.
警告

Only technicians who have completed all required certification courses are permitted to perform this procedure. Tesla recommends third party service provider technicians undergo equivalent training before performing this procedure. For more information on Tesla Technician requirements, or descriptions of the subject matter for third parties, see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points for additional safety information.

扭矩规格

表 1. 扭矩规格: 烟火电池断接开关(拆卸和更换)
描述 扭矩值 推荐工具 重复使用/更换 备注
Bolts that attach the pyrotechnic battery disconnect to the HV battery
  • Torque bolts to
    15 Nm (11.1 lbs-ft)
  • Reverse bolts by 180°
  • Retorque the bolts to
    5 Nm (3.7 lbs-ft)
  • Torque bolts an additional 60°
  • Insulated tools:
    • 13 mm 套筒
更换

拆卸

  1. 拆下高压电池仓盖板。请参阅盖板 - 高压电池仓(拆卸和安装)。
    警告
    HV insulating gloves and leather glove protectors must be worn throughout the remainder of this procedure. Do not remove gloves or protectors until otherwise noted.
  2. 拆下烟火电池断接开关分流器绝缘体。
    图 1. 第 1 代
    图 2. 第 2 代
  3. 拆下并弃用将烟火电池断接开关固定到高压电池的螺栓,然后将烟火电池断接开关从车辆上拆下。
  4. 在拆下烟火电池断接开关的位置上,安装虚拟断接开关。

安装

  1. 对 Hioki 电阻计执行零点调节,以便稍后在此程序中测量电阻。请参阅 电阻表(零点调节)。
    警告
    HV insulating gloves and leather glove protectors must be worn throughout the remainder of this procedure. Do not remove gloves or protectors until otherwise noted.
  2. 在将要安装烟火电池断接开关的位置上,拆下虚拟断接开关。
  3. 使用异丙醇 (IPA) 湿巾清理分流器、母排以及烟火电池断接开关的高压接合面。
  4. 将万用表设置到 "LoZ"(低阻抗)模式。
    注
    若为模式选择器上没有 "LoZ" 模式的 Fluke 万用表,请参阅万用表(LoZ 设置)。
  5. 测量母排(左)与分流器(右)之间的电压至少 10 秒,以平衡烟火电池断接开关安装点之间的电压。
    注
    万用表上显示的电压不如平衡安装点电压重要。
  6. 测量电压期间,请助手帮忙将烟火电池断接开关放置到高压电池内,以备安装。务必将连接器针脚与新的烟火电池断接开关对齐,然后将烟火电池断接开关向下按压到母排上。
  7. 将烟火电池断接开关置于母排上后,继续测量电压 10 秒。
  8. 安装新的螺栓,将烟火电池断接开关固定到高压电池。
    1. 将螺栓预先拧至 15 Nm。
    2. 将螺栓回拧 180 度。
    3. 重新紧固至 5 Nm。
    4. 再紧固 60 度。
    5. 用油性记号笔标记螺栓。
    提示
    推荐使用以下工具
    • Insulated tools:
      • 13 mm 套筒
  9. 使用 Hioki 电阻计测量新安装的烟火电池隔离开关与左侧母排之间高压连接点的电阻。
    注
    最大可接受电阻值为 0.060 毫欧(60 微欧)。高压接头电阻过大。拆下紧固件,使用异丙醇清洁接触区域,重新安装紧固件,再次测试
  10. 使用 Hioki 电阻计测量新安装的烟火电池断接开关与分流器之间高压接头的电阻。
    注
    最大可接受电阻值为 0.045 毫欧(45 微欧)。高压接头电阻过大。拆下紧固件,使用异丙醇清洁接触区域,重新安装紧固件,再次测试
    图 3. 一般测量 - 实际的母排和紧固件可能有所不同
  11. 安装烟火电池断接开关分流器绝缘体。
    图 4. 第 1 代
    图 5. 第 2 代
  12. 将高压电池仓维修盖板从高压电池仓上取下。
  13. 安装高压电池仓盖板。请参阅盖板 - 高压电池仓(拆卸和安装)。