卡入式通风口 - 高压电池 - 左侧 ((拆卸和更换))

校正代码 16102122 FRT 0.66 注意:除非本程序中另有明确规定,否则上文所列校正代码及相关 FRT 反映的是执行本程序(包括关联程序)所需的所有工作。除非明确要求,否则请勿堆叠校正代码。 注意:请参阅平均维修工时深入了解 FRT 及其创建方式。 注意:请参阅人员保护确保在执行以下程序时穿戴适当的个人防护装备 (PPE)。 注意:请参阅人体工程学注意事项查看安全健康的作业规程。

警告
Only technicians who have completed all required certification courses are permitted to perform this procedure. Tesla recommends third party service provider technicians undergo equivalent training before performing this procedure. For more information on Tesla Technician requirements, or descriptions of the subject matter for third parties, see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points for additional safety information.

拆卸

  1. 举升并支撑车辆
  2. 执行车辆高压禁用程序。请参阅 车辆高压禁用程序。
  3. 将左侧高压电池快接通风口总成从高压电池上拆下并弃用。
    注
    从内部撬动 2 个锁片,以松开通风口总成。

安装

  1. 使用异丙醇清洁快接通风口的接触表面。等待风干 1 分钟。
  2. 检查高压电池快接通风口,如损坏则请更换。
  3. 将新的通风口总成放置在电池上,然后将左侧通风口总成安装到高压电池上。
    提示
    先插入外侧,然后向前压入内侧。通风口完全接合时会发出清晰的锁止声。
  4. 执行磁盘外壳漏气测试。请参阅 磁盘外壳漏气测试。
    注
    使用新的高压电池快接通风口总成进行替换时,无需将通气阀塞从两个热通风口上拆下。
  5. 连接低压电源。请参阅 12V/低压电源(断开和连接)。