Low Internal Isolation Diagnostics - HV System (Test)
校正代码 44500300600 0.90 注意: 除非本程序中另有明确规定,否则上文所列校正代码和 FRT 反映的是执行本程序(包括关联程序)所需的所有工作。 除非明确要求,否则请勿堆叠校正代码。 注意: 请参阅平均维修工时深入了解 FRT 及其创建方式。 注意: 请参阅人员保护确保在执行以下程序时穿戴适当的个人防护装备 (PPE)。 注意: 请参阅人体工程学注意事项查看安全健康的作业规程。
警告
本程序为“草案”。虽已通过验证,但可能仍有“警告”和“注意”事项缺失。请遵守安全要求,处理或靠近高压系统和部件时,请谨慎操作。
- 2026-03-18: Released new procedure.
-
Prepare for HV battery removal
注Due to the potential issues associated with an isolation fault, customer and/or insurance approval is not needed to remove the HV battery while investigating the fault, For high voltage battery packs that have a low internal isolation condition and/or liquid ingress, It is crucial to remove the fluid promptly, HV gloves, Leather over-gloves, Safety glasses, And safety shoes must be worn at all times while handling a vehicle and/or HV battery pack with an internal isolation condition, Refer to Toolbox article 7410000
-
Remove all items from pockets and ensure not wearing metal items
-
Inspect HV insulating gloves
注Check gloves for damage prior to use, Refer to service document TN-15-92-003, for information on inspecting HV gloves.
-
Put on HV insulating gloves and leather over gloves
注Use HV cut resistant insulated gloves or HV insulating gloves and leather over gloves, HV Insulating gloves must be worn any time a Hioki Tester or Hi-Pot Tester is used, Refer to service document TN-15-92-003 R5 for PPE requirements depending on vehicle configuration.
-
Secure vehicle outside of workshop
注Secure vehicle in an outdoor area with 15M of space around it in every direction
-
Install wheel chocks onto rear wheels
注See HV battery RR procedure for steps
-
Release electronic parking brakes
注See HV battery RR procedure for steps
-
Power down vehicle
注Refer to HV battery RR procedure for steps
-
Download and Install PCAN driver
注After software has been downloaded install drivers to laptop.
-
Connect CAN dongle to laptop via USB port
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注1x connector
-
Connect HV battery communication harness to HVC and CAN dongle
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注2x connector, ensure the PCAN is connected to the VEH CAN breakout
-
Connect battery communication harness to power supply
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注Use the 12V output of the power bank
-
Connect phone to charging cable and charging cable to power supply
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注2x connector, Press ''ON'' to turn ON the power bank. This is necessary to prevent the power bank from shutting down automatically if only connected to the BMS, which does not draw enough power for the power bank to remain powered / active.
-
Open HV Battery Communication Tool in Toolbox
注Navigate to the HV Battery Communication Tool on the left hand Toolbox menu
-
Check that PCAN is detected by laptop
注If PCAN is detected there will be a message on top of the HV Battery Communication Tool, "Select an ECU depending on the HV battery type. Press the Help button for more info on ECU compatibility."
-
Select ECU
注Select HVBMS ECU in drop down menu
-
Check HV Battery vitals
注Refer to Toolbox article 41977, The HV vitals are not stable if any of the following is true:Module temperatures are significantly higher than ambient temperature.Module temperatures min and max deviate from each other more than 5 degrees C.Brick voltages min and max deviate more than 20 mV.If vitals are not stable, isolate the pack or vehicle in 30 meter bubble.
-
Disconnect phone and phone charging cables from power supply
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注2x connector
-
Disconnect battery communication harness from power supply
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注1x connector
-
Disconnect HV battery communication harness from HVC and CAN dongle
警告Do not place anything on top of the HV battery other than the high voltage “Danger” placard注2x connectors
-
Disconnect CAN dongle from laptop
注1x connector
-
Prepare work area
注Prepare a workspace around a two post lift with nearby access to HV PPE, Battery table, and necessary tooling
-
Remove high voltage battery pyro disconnect
注See HV battery RR procedure for steps
-
Remove rocker covers
注Refer to removal steps in HV battery RR procedure
-
Install Universal Lift Pad Adapters onto lift arms
注4x adapters, Refer to removal steps in HV battery RR procedure
-
Raise vehicle fully and lower lift onto locks
注Set vehicle to comfortable working height, Ensure an audible click of locks on both sides is heard before lowering, Vehicle may tilt to the side if both locks are not engaged
-
Inspect HV battery for dents, fluid leaks, or other signs of instability
注If found, refer to Toolbox article 7396600
-
Inspect HV battery for coolant leaks or fluid ingress
注Refer to Toolbox article 40073, If liquid ingress is found then proceed to HV battery removal, If HV battery removal is not possible continue procedure with pack in vehicle, Continue to relevant procedure for fluid ingress removal as needed
-
Remove rear battery enclosure skid plate from HV battery pack
注See HV battery RR procedure for steps
-
Remove LH flood port 2.0 from HV battery
注8x tabs, Rotate as needed so that the relief is accessible, Pry between the enclosure and flood port
-
Remove RH flood port 2.0 from HV battery
注8x tabs, Rotate as needed so that the relief is accessible, Pry between the enclosure and flood port
-
Remove HV battery breather assemblies
注6 nuts, 10 mm, 9 Nm
-
Inspect HV battery for moisture ingress
注Inspect breather and interior of battery for moisture ingress, If moisture ingress is present then proceed to HV battery replacement
-
Remove HV battery from vehicle
注Refer to HV battery removal procedure for applicable vehicle model
-
Move HV battery to a suitable work area
注Hv battery must have 15M of space around it in every direction
-
Place HV Danger placard on top of battery
-
Place barricades around work area
注Note location of extinguishers and HV rescue hook
-
Ensure entire work area is clear
注Including above and below battery
- Remove HV insulating gloves