2026-08-09

盖 - 高压探针 - 高压电池(拆卸和更换)

\校正代码16101602 0.36 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and its associated FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See 人员保护 to make sure wearing proper PPE when performing the below procedure. NOTE: See 人体工程学注意事项 for safe and healthy working practices.

设备:
  • 1059330-00-B Skt, 1/4in Dr, 5-Lobe Torx Plus External
警告

Only technicians who have completed all required certification courses are permitted to perform this procedure. Tesla recommends third party service provider technicians undergo equivalent training before performing this procedure. For more information on Tesla Technician requirements, or descriptions of the subject matter for third parties, see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness Care Points for additional safety information.

扭矩规格

表 1. 扭矩规格: 盖 - 高压探针 - 高压电池(拆卸和更换)
描述 扭矩值 推荐工具 重复使用/更换 备注
Bolt that attaches the HV probe cover to the ancillary bay cover
6 Nm (4.4 lbs-ft)
  • 外梅花 5 角套筒 E10
更换
注
紧固后,使用油性记号笔标记紧固件。

拆卸

  1. 断开 12V 电源。请参阅12V/低压电源(断开和连接)。
  2. 拆卸并弃置将高压探针盖固定到高压电池仓盖板的五角螺栓(2 个),然后从高压电池仓盖板上拆下高压探针盖。

安装

  1. 用异丙醇 (IPA) 湿巾清洁高压探针盖密封件表面以及高压电池仓盖板装配面。
  2. 目视检查高压探针盖垫圈与高压电池仓盖板装配面,检查是否存在裂痕、切口、凹陷、磨损以及任何影响密封性的损坏痕迹。
    注
    如果高压探针盖垫圈出现任何破损,请更换垫圈。如果高压电池仓盖板装配面存在可能影响密封性的轻微破损,需按照要求执行高压电池仓漏气测试。
  3. 将高压探针盖安装到高压电池仓盖板上,安装新的五角螺栓(2 个),将高压探针盖固定至高压电池仓盖板。拧紧螺栓后,使用油漆笔做下标记。
    6 Nm (4.4 lbs-ft)
  4. 如果在高压电池仓盖板装配面上发现轻微破损,请适时执行高压电池仓漏气测试。请参阅高压电池仓漏气测试 (Inspection)。
    注
    如将拆下高压电池仓盖板,请在安装高压电池仓盖板后再执行高压电池仓漏气测试。
  5. 连接 12V 电源。请参阅12V/低压电源(断开和连接)。