Vehicle HV Disablement Procedure (7-Seat)
교정 코드 17010000 FRT 0.48 메모: 절차에서 명시적으로 언급하지 않는 한 교정 코드 및 해당 관련 FRT는 연결된 절차를 포함하여 이 절차를 수행하는 데 필요한 모든 작업을 반영합니다. 명시적으로 지시하지 않는 한 교정 코드를 누적하지 마십시오. 참고: FRT와 그 생성 방법에 대한 자세한 내용은 표준 정비 작업시간의 내용을 참조하십시오. 참고: 아래 절차를 수행할 때 개인 보호의 내용을 참조하여 적절한 PPE를 착용했는지 확인하십시오. 참고: 안전하고 건강한 작업 사례는 인체공학적 주의 사항의 내용을 참조하십시오.
Only
technicians who have completed all required certification courses are permitted to
perform this procedure. Tesla recommends third party service provider technicians
undergo equivalent training before performing this procedure. For more information on
Tesla Technician requirements, or descriptions of the subject matter for third parties,
see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV
gloves with a minimum rating of class 0 (1000V) must
be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness
Care Points
for additional safety
information.
Equipment:
- 1754057-00-A - CURRENT PROBE, GEN, CLAMP, DC, 600V
- 1083188-01-B - Digital Multimeter Unit, EXTECH 355
- 1130480-02-B - Slim Test Probes, CAT III 1000V
절차
- Disconnect LV power. See LV Power (Disconnect and Connect) (Modify).
-
Set the multimeter to measure voltage,
and then measure the voltage across the LV auxiliary battery terminals.
CAUTIONIf the voltage across the battery terminals is less than 13 volts or greater than 16 volts, the multimeter is not measuring reliably and must not be used.
- Remove the rear aero shield. SeeAero Shield - Rear (Remove and Replace) .
- Remove rear skid plate. See Skid Plate - Rear (Remove and Replace).
-
Install the current clamp meter onto
one cable of the rear drive unit HV harness.
NoteMake sure the meter is facing the correct direction as shown.
-
Measure the current in the HV
cable.
- If the current is within the range of -0.5 A to 0.5 A, continue to the next step.
- If the current is outside the range of -0.5 A to 0.5 A, for example -0.8 A or 1.3 A, re-perform the vehicle electrical isolation again to make sure that all was properly shut down. If the measurement is still outside the range of -0.5 A to 0.5 A, escalate for assistance.
WarningDO NOT DISCONNECT any HV harness when the current measurement is outside the range of -0.5 A to 0.5 A. -
Remove the nut that attaches the rear
drive unit HV cable bracket to the HV battery.
NoteThe number of the fasteners may vary.Tip다음 공구를 사용하는 것이 좋습니다.
- 10mm 소켓
- Remove all jewelry and empty your pockets before continuing this procedure.
- Inspect and put on HV insulating gloves, leather outer gloves, and safety glasses before continuing this procedure.
-
Disconnect the connector that attaches
the rear drive unit HV cable to the HV battery.
NoteRelease the locking tab and rotate the release lever up to disengage the connector. Do not force the release lever up. Ensure the alignment tabs on the rear drive unit header are not damaged.
-
Use the high voltage multimeter with
CAT III probes to verify that no high voltage is present at the rear drive unit HV
header.
Measure the following voltages:WarningIn order to limit potential exposure to high voltage, measure for high voltage in the order specified below.
- B+ to ground
- B- to ground
- B+ to B-
WarningIf any voltage is greater than 10V, the contactors are closed or welded. Escalate to Service Engineering. -
Make sure the connector lock is 90
degrees from the connector, and then connect the connector that attaches the rear drive
unit HV cable to the HV battery.
NoteUse one hand to support the connector while the other latching the locking tab. Once installed, verify that the latch is not damaged and is fully secured in the latched position.
- Remove the leather over gloves and the HV insulating gloves.
-
Install the nut that attaches the rear
drive unit HV cable bracket to the HV battery.
NoteThe number of the fasteners may vary.Tip다음 공구를 사용하는 것이 좋습니다.
- 10mm 소켓
- Install the rear skid plate. See Skid Plate - Rear (Remove and Replace).
- Install the rear aero shield. SeeAero Shield - Rear (Remove and Replace) .
- Connect LV power. See LV Power (Disconnect and Connect) (Modify).