18/12/2023 19:28:32

母排 - 输出 - 正极 - 快充 - 高压电池(结构化电池组)(拆卸和更换)

校正代码 16307202 1.92 注意:除非本程序中另有明确规定,否则上述校正代码和 FRT 反映的是执行本程序(包括关联程序)所需的所有工作。除非明确要求,否则请勿堆叠校正代码。注意:请参阅平均维修工时,深入了解 FRT 及其创建方式。要提供有关 FRT 值的反馈,请发送电子邮件至LaborTimeFeedback@tesla.com注意:请参阅人员保护,确保在执行以下程序时穿戴适当的个人防护装备 (PPE)。

Warning IconA warning icon, calling your attention to a possibly risky situation
警告
尽管此程序已经过验证,但仍是一个草案。可能没有警告和注意事项。请遵守安全要求,处理或靠近高压系统和部件时,请谨慎操作。请将校正修理内容及反馈发送至ServiceDevelopment@teslamotors.com
  1. Open all four doors
  2. Lower all four windows
  3. Place vehicle in service mode with touchscreen
    Informational PurposesAn informational icon, calling your attention
    Hold Tesla T icon at top of center display for four seconds and then type "service" into dialog box
  4. Remove the ancillary bay cover. See 盖板 - 高压电池仓(结构化电池组)(拆卸和更换).
  5. 拆下烟火电池隔离开关。请参阅烟火电池断接开关(结构化电池组)(拆卸和安装)
  6. Disconnect fast charge contactor
    Informational PurposesAn informational icon, calling your attention
    1x connector, Push on both side of connector to release tabs and pull upward
  7. Remove bolt securing AC filter harness to negative DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x bolt, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Discard after removal
  8. Remove bolt securing AC filter harness positive DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x bolt, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Discard after removal
  9. Release AC filter harness from tray
    Informational PurposesAn informational icon, calling your attention
    2x clips
  10. Remove FC contactor cover
    Informational PurposesAn informational icon, calling your attention
    3x securing tabs
  11. Remove bolts securing FC positive outlet jumper
    Informational PurposesAn informational icon, calling your attention
    2x bolts, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Discard after removal
  12. Remove FC positive outlet jumper from ancillary bay
  13. Position FC positive outlet jumper onto ancillary bay
  14. Install bolts securing FC positive outlet jumper
    Informational PurposesAn informational icon, calling your attention
    2x bolts, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Discard after removal
  15. Perform Hioki measurement at the joint from FC positive outlet jumper busbar to DC positive link busbar
    Informational PurposesAn informational icon, calling your attention
    1 HV joint, 60µΩ or less
  16. Install FC contactor cover
    Informational PurposesAn informational icon, calling your attention
    3x securing tabs
  17. Install bolt securing AC filter harness positive DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x bolt, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Install new bolt
  18. Install bolt securing AC filter harness to negative DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x bolt, 13mm, 15 Nm, Minus 180 degrees, 5 Nm + 60 degrees, Install new bolt
  19. Perform Hioki impedance measurement at joint from AC filter harness to positive DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x HV joint, 150µΩ or less
  20. Perform Hioki impedance measurement at joint from AC filter harness to negative DC inlet busbar
    Informational PurposesAn informational icon, calling your attention
    1x HV joint, 150µΩ or less
  21. Secure AC filter harness onto tray
    Informational PurposesAn informational icon, calling your attention
    2x clips
  22. Connect fast charge contactor
    Informational PurposesAn informational icon, calling your attention
    1x connector, Push on both side of connector to release tabs and pull upward
  23. 测量烟火电池隔离开关安装点间的电压,然后安装烟火电池隔离开关。请参阅烟火电池断接开关(结构化电池组)(拆卸和安装)
  24. Install the ancillary bay cover. See 盖板 - 高压电池仓(结构化电池组)(拆卸和更换).
  25. Exit Service Mode through UI
    Informational PurposesAn informational icon, calling your attention
    Controls > Service Mode > Exit Service Mode
  26. Raise all four windows
  27. Close all four doors
    Informational PurposesAn informational icon, calling your attention
    If 12V is powered up, Unlatch rear doors before closing