08/04/2024 19:53:20

Event Data Recorder Retrieval

校正代码 NA

Warning IconA warning icon, calling your attention to a possibly risky situation
警告
尽管此程序已经过验证,但仍是一个草案。可能没有警告和注意事项。请遵守安全要求,处理或靠近高压系统和部件时,请谨慎操作。请将校正修理内容及反馈发送至ServiceDevelopment@teslamotors.com
Informational PurposesAn informational icon, calling your attention
Refer to CD-20-20-001 for Model Y Event Data Recorder (EDR) guide.
Informational PurposesAn informational icon, calling your attention
Use the following procedure(s) for Model Y Non-Structural Pack EDR retrieval as required:
Informational PurposesAn informational icon, calling your attention
Use the following procedure(s) for Model Y Structural Pack EDR retrieval as required:

Establish a Direct-to-Module Connection (Non-Structural Pack)

  1. Open all of the doors.
  2. Lower all of the windows.
  3. On the vehicle touchscreen, select the Tesla symbol, and then confirm and note the vehicle’s firmware version.
    图 1. Model 3 shown; Model Y similar
  4. Remove the Restraint Control Module (RCM). See 模块 - 约束控制(非结构化电池组) (拆卸和更换).
  5. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    推荐使用以下工具:
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  6. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    推荐使用以下工具:
    • PCAN USB to CAN adapter - 1016990-00-A
  7. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  8. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  9. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  10. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  11. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    EDR retrieval time will vary based on the user and retrieved data.
  12. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  13. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  14. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  15. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  16. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  17. Install the RCM. See 模块 - 约束控制(非结构化电池组) (拆卸和更换).
  18. Raise all of the windows.
  19. Close all of the doors.

Establish a Direct-to-Module Connection (Structural Pack)

  1. Remove the RCM. See 模块 - 约束控制(结构化电池组)(拆卸和更换).
  2. Connect the EDR extraction harness connectors (x2) to the RCM.
    Informational PurposesAn informational icon, calling your attention
    推荐使用以下工具:
    • EDR extraction harness, RCM, Bosch MS-M3-MY - 1492139-00-B
  3. Connect the EDR extraction harness connector to the PCAN USB to CAN adapter connector.
    Informational PurposesAn informational icon, calling your attention
    推荐使用以下工具:
    • PCAN USB to CAN adapter - 1016990-00-A
  4. Connect the PCAN USB to CAN adapter dongle connector to the laptop USB port.
  5. Connect the XP-20 (heavy duty) jump start 12V power to the EDR extraction harness.
    Informational PurposesAn informational icon, calling your attention
    Jump start, XP-20 (heavy duty) - 1016990-00-A
  6. Open the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    The program will automatically try to connect to RCM and will display a green circle in the lower left corner when connected.
  7. Once the Tesla EDR Retrieval Program connection is established, click "Run EDR Retrieval", and then follow the on-screen prompts to retrieve and save the EDR data.
  8. Use the retrieved data to "Generate a Report". See https://edr.tesla.com.
    Informational PurposesAn informational icon, calling your attention
    EDR retrieval time will vary based on the user and retrieved data.
  9. Close the Tesla EDR Retrieval Program.
    Informational PurposesAn informational icon, calling your attention
    Select "X" at the top right of the window to close the program once EDR retrieval is complete.
  10. Disconnect the XP-20 (heavy duty) jump start 12V power from the EDR extraction harness.
  11. Disconnect the PCAN USB to CAN adapter dongle connector from the laptop USB port.
  12. Disconnect the EDR extraction harness connector from the PCAN USB to CAN adapter connector.
  13. Disconnect the EDR extraction harness connectors (x2) from the RCM.
  14. Install the RCM. See 模块 - 约束控制(结构化电池组)(拆卸和更换).