2025-01-16

Trunk Floor Assembly (Complete)

Repair Procedure

  1. Remove the original component.
    or Factory Spot Welds

    or Factory SPRs

  2. Prepare for installation.
    Informational PurposesAn informational icon, calling your attention
    Note
    A red X indicates a location where a factory-installed fastener is not being replaced.

    or High Strength Structural Rivets, 6.5 mm

    or Structural Bulb Rivets, 6.5 mm
    • A = 29 mm.
    • B = 14 mm.
  3. Apply structural adhesive to the mating surfaces on the vehicle and the new component or components.
  4. Install the new component or components.