A/C Line - Supermanifold to HVAC (Remove and Replace)
Correction code
18201702
0.42
NOTA: Salvo explicitamente indicado em contrário no procedimento, o código de correção acima e o FRT refletem todo o trabalho necessário para a realização deste procedimento, incluindo os procedimentos associados. Não acumule códigos de correção, salvo se explicitamente instruído.
NOTA: Consulte Tempos de taxa fixa para saber mais sobre FRT e sobre a respetiva criação.
NOTA: Consulte Proteção pessoal para garantir que utiliza o EPI adequado durante a realização do procedimento abaixo. NOTA: Consulte para conhecer as práticas seguras e saudáveis de trabalho.
- 2024-09-12: Added note on adding correction code for refrigerant - recovery/recharge as a separate activity to the Service Visit.
- 2024-02-28: Updated the routines.
Torque Specifications
| Description | Torque Value | Recommended Tools | Reuse/Replace | Notes |
|---|---|---|---|---|
| Bolts that attach the supermanifold to HVAC A/C line to the HVAC assembly |
![]() 28 Nm (20.6 lbs-ft) |
|
Reuse | |
| Nut that attaches the supermanifold to HVAC A/C line to the supermanifold |
![]() 36 Nm (26.5 lbs-ft) |
|
Reuse |
Remove
- Remove the underhood storage unit. See Underhood Storage Unit (Remove and Replace).
- Remove the HEPA filter. See .
- Recover the A/C refrigerant. See .
- Remove the fresh intake duct. See Duct - Fresh Intake (Remove and Replace).
- Remove the 12V/LV auxiliary battery. See .
-
Remove the bolts (x2) that attach the
supermanifold to HVAC A/C line to the HVAC assembly.
TIpUse of the following tool(s) is recommended:
- 13 mm socket
-
Remove the nut that attaches the
supermanifold to HVAC A/C line to the supermanifold.
TIpThis nut is behind the supermanifold to compressor A/C line.TIpUse of the following tool(s) is recommended:
- 13 mm socket
-
Release the supermanifold to HVAC A/C
line from the supermanifold, and then move the A/C line rearwards and up to remove
it.
Install
-
Position the supermanifold to HVAC A/C
line on the supermanifold, inserting the A/C line stud into the stud hole on the
supermanifold.
TIpReach under the supermanifold to position the A/C line.TIpLook through the supermanifold stud hole to help locate the A/C line stud.
-
Install the nut that attaches the
supermanifold to HVAC A/C line to the supermanifold.
36 Nm (26.5 lbs-ft)TIpThis nut is behind the supermanifold to compressor A/C line.TIpUse of the following tool(s) is recommended:- 13 mm socket
-
Install the bolts (x2) that attach the
supermanifold to HVAC A/C line to the HVAC assembly.
28 Nm (20.6 lbs-ft)TIpUse of the following tool(s) is recommended:- 13 mm socket
- Begin the vacuum leak test and then return to this procedure. See #TASK_AWW_PQM_TLB.
- Install the 12V/LV auxiliary battery. See .
- Install the fresh intake duct. See Duct - Fresh Intake (Remove and Replace).
- When the vacuum leak test is complete, inject the appropriate amount of oil back into the A/C system. See #TASK_AWW_PQM_TLB.
- Recharge the A/C refrigerant. See #TASK_QGF_HNZ_QLB.
- Connect 12V/LV power. See 12V/LV Power (Disconnect and Connect).
- Unlock the vehicle gateway. See .
- On the touchscreen, touch and select Run, and then allow the routine to complete.
- Tap , select Run, and allow the routine to complete.
- Tap , select Run, and allow the routine to complete.
- Exit Service Mode. See .
- Install the HEPA filter. See .
- Install the underhood storage unit. See Underhood Storage Unit (Remove and Replace).