HV Controller (Model Y L) (Remove and Replace)
Correction code
16300500002
FRT
1.74
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
Equipment:
- 1467483-00-C - M3/Y Penthouse Service Insulator Kit
- 1108272-00-B - CAP, LOGIC CONN, INV, 3DU
Remove
- Perform a backup of the high voltage controller data. See Controller - High Voltage (Backup and Restore).
- Remove the high voltage controller. See GUID-09250105-375F-4932-9682-3EF63F541E5E.html.
Replace
-
Install the high voltage controller. See GUID-09250105-375F-4932-9682-3EF63F541E5E.html.
NoteDo not connect the LV battery and do not install the HEPA assembly at this step.
- Connect the LV maintainer charger. See LV Maintainer (Connect and Disconnect) (Maintenance).
- Restore the high voltage controller data. See Controller - High Voltage (Backup and Restore).
- Disconnect the LV maintainer, connect the LV battery, and install the HEPA assembly. See LV Maintainer (Connect and Disconnect) (Maintenance) and HEPA Filter Assembly (Remove and Replace).