车辆高压禁用程序(七座)
校正代码 17010010 0.30 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and its associated FRT reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See 人员保护 to make sure wearing proper PPE when performing the below procedure. NOTE: See for safe and healthy working practices.
- 2025-11-26: 添加了“执行需要接触高压部件以完成高压禁用的程序时,请全程佩戴高压绝缘手套”的说明。
- 2024-12-20: 添加了设置钳型表以测量直流的说明。
- 2024 年 6 月 5 日:添加了“按照指定的位置顺序测量高压”的警告。
- 2023 年 12 月 5 日:更新了其他车辆隔离程序参考。
- 2023 年 11 月 8 日:添加了/更新了高压绝缘手套相关步骤。
- 2023 年 5 月 2 日:更新了电流测量步骤顺序和一致性。
Only
technicians who have completed all required certification courses are permitted to
perform this procedure. Tesla recommends third party service provider technicians
undergo equivalent training before performing this procedure. For more information on
Tesla Technician requirements, or descriptions of the subject matter for third parties,
see HV Certification Requirements. Proper personal protective equipment (PPE) and insulating HV
gloves with a minimum rating of class 0 (1000V) must
be worn at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003, High Voltage Awareness
Care Points
for additional safety
information.
设备:
- 1146175-00-A 电流钳,Fluke 374FC
- 1130480-02-B 纤细测试探针
隔离
- 打开所有车门,降下所有车窗。
- 拆卸前备箱后部挡板。请参阅前备箱挡板 - 后部(拆卸和更换)。
- 断开 12V 电源/低压电源请参阅12V/低压电源(断开和连接)。
-
设置电流钳以测量电压,然后使用测试探针测量 12V/低压辅助电池端子间的电压。
注对于低压(锂离子)辅助电池:如果电池端子间的电压为 0,则说明电池可能已在内部关闭。使用 12V 铅酸电池进行测试。对于移动服务技术人员:使用移动服务车辆中的 12V 铅酸电池。警告对于低压(锂离子)辅助电池:如果电池端子间的电压低于 13V 或高于 16V,则说明电流钳的测量不可靠,请勿使用它。警告对于 12V(铅酸)辅助电池:如果测得的电压低于 10V 或高于 14V,则说明电流钳的测量不可靠,请勿使用它。
- 拆卸中间流线型护板。请参阅面板 - 流线型护板 - 后部(拆卸和更换)。
- 拆下电池后滑板。请参阅。
-
取出口袋中的所有物品并确保未佩戴金属饰品。
-
检查高压绝缘手套。
注使用前检查手套是否损坏;请参阅服务文档 TN-15-92-003 R1,了解有关检查高压绝缘手套的信息。
-
请佩戴高压绝缘手套、皮质外手套和护目镜。
警告请继续佩戴手套,操作说明允许摘掉时方可脱下。
-
接通电流钳仪表的电源,然后将仪表调零,以便测量。
警告确保设置钳型表以测量直流电流 ("Adc")。
-
将电流钳仪表安装到后驱动电机高压线束的一条电缆上。
注确保仪表朝向正确。
-
测量高压电缆中的电流。
- 如果电流在 -0.5A 至 0.5A 范围内,请继续执行下一步。
- 如果电流超出 -0.5A 至 0.5A 的范围,例如 -0.8A 或 1.3A,请重新执行低压电源断开程序。请参阅12V/低压电源(断开和连接)。如果测量值仍超出 -0.5A 至 0.5A 的范围,请上报以寻求帮助。警告如果电流测量值超出 -0.5A 至 0.5A 的范围,请勿断开任何高压线束。
-
拆下将后驱动电机高压线缆支架固定到高压电池的螺母。
-
将后驱动电机高压电缆从高压接头上断开。
注松开锁片,然后向上转动释放杆以便松开连接器。请勿强行提起释放杆。确保后驱动电机接头上的对齐锁片没有损坏。
-
Verify no high voltage at the rear drive unit HV header.
警告In order to limit potential exposure to high voltage, measure for high voltage in the order specified below.注Verify test equipment is rated CATIII or higher. Measure B+ to Ground, B- to Ground, B+ to B-. If the voltage is greater than 10V, the pack contactors are not open or welded. Stop work and reach out to Service Engineering.
Measurement Order Component Test
B+
(LH probe opening)
B-
(RH probe opening)
GND
Measured Voltage Less Than 10 V
Measured Voltage 10 V Or More
1 HV battery positive contactor
Positive (+) Lead
Negative (-) Lead on screw that attaches the RDU HV header to the HV battery
Pass
Fail
2 HV battery negative contactor
Positive (+) Lead
Negative (-) Lead on screw that attaches the RDU HV header to the HV battery
Pass
Fail
3 HV
Positive (+) Lead
Negative (-) Lead
Pass
Fail
图 1. B+ to GND measurement 图 2. B- to GND measurment 图 3. B+ to B- measurment -
返回至相应程序,以使车辆处于电气隔离状态。
警告Follow all safety instructions and PPE requirements of the procedure that required the vehicle to be electrically isolated. Do not remove the HV gloves if the procedure requires you to handle high voltage cables, busbars, or fittings.注如果确定不再会接触高压,则可脱下高压绝缘手套。
集成
-
如果已脱下高压绝缘手套和皮质外手套,请将其戴上。
-
将后驱动电机高压电缆连接到高压电池。
注确保在固定连接器前,连接器锁与连接器呈 90 度角。使用一只手撑起连接器,另一只手锁定锁片。安装后,确认闩锁未损坏且完全固定在锁止位置。
- 脱下皮革手套保护罩和高压绝缘手套。
-
安装将后驱动电机高压线缆支架固定到高压电池的螺母。
10 Nm (7.4 lbs-ft) - 安装电池后滑板。请参阅。
- 安装中间流线型护板请参阅面板 - 流线型护板 - 后部(拆卸和更换)。
- 连接 12V/低压电源。请参阅12V/低压电源(断开和连接)。
- 安装前备箱后挡板。请参阅前备箱挡板 - 后部(拆卸和更换)。
- 升起所有车窗,关闭所有车门。