Mid Circuit Interrupter Specifications (P/N MCI-1) PV Rapid Shutdown Equipment (PVRSE)
Electrical Specifications
Nominal Input DC Current (IMP) | 13 A |
Maximum Input Short Circuit Current (ISC) | 19 A |
Maximum System Voltage | 600 V DC |
RSD Module Interface
Maximum MCI per String | 5 |
Control | Power Line Excitation |
Passive State | Normally open |
Maximum Power Consumption | 7 W |
Compliance Information
Certifications | UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) |
RSD Initiation Method | External System Shutdown Switch or On/Off Enable switch located on Powerwall 3, when labeled as Rapid Shutdown Initiator per NEC 690.12 requirements |
UL 3741/PVRSA Compatible Equipment | UL 3741 Systems using Powerwall 3 and MCI |
Environmental Specifications
Ambient Temperature | -40°F to 122°F (-40°C to 50°C) |
Storage Temperature | -22°F to 158°F (-30°C to 70°C) |
Enclosure Rating | NEMA 4X / IP65 |
Mechanical Specifications
Electrical Connections | MC4 Connector |
Housing | Plastic |
Height | 5 inches (125 mm) |
Width | 6 inches (150 mm) |
Depth | 1 inches (22 mm) |
Weight | 0.77 lb (350 g) |
Mounting Options |
Zep Home Run Clip |