Vehicle HV Disablement Procedure
Correction code 17010000 0.30 NOTA: Salvo diversa ed esplicita indicazione nella procedura, il codice modifica e il tempo forfettario, o FRT, riflettono tutto il lavoro richiesto per l'esecuzione di questa procedura, incluse le procedure collegate. Non cumulare i codici modifica a meno che non venga detto esplicitamente di farlo. NOTA: Consultare la Tempistica tariffe fisse per saperne di più sui tempi forfettari e su come essi vengono creati. NOTA: Consultare Protezione personale per assicurarsi di indossare i DPI adatti quando si esegue la procedura descritta di seguito. NOTA: Vedere per le pratiche di lavoro in sicurezza.
- 2025-11-26: Added note to keep HV gloves on if procedure that required disablement involves touching HV components.
- 2025-10-22: Added info in measurement table on GND point to be used for Negative (-) Lead, modified measurement sequence.
- 2025-03-24: Added warning for regional tooling regulations.
- 2025-01-30: Clarified B+ and B- probe step.
- 2024-10-21: Rearranged multimeter probing images to align with HV measurement table.
- 2024-06-05: Added warning to measure the specified order of locations for high voltage.
- 2023-12-12: Updated voltage measurement order.
- 2023-11-08: Added/updated HV insulating glove steps.
- 2023-06-29: Added the whole procedure video as an overview for supplemental purposes only.
- 2023-08-30: Added a tip about replacing the probe to the multimeter-related step.
Solo i tecnici che hanno completato tutti i corsi di certificazione richiesti sono autorizzati a eseguire questa procedura. Tesla raccomanda ai tecnici di fornitori di terze parti di seguire una formazione equivalente prima di svolgere la presente procedura. Per maggiori informazioni sui requisiti dei Tecnici Tesla, o per le descrizioni degli argomenti richiesti per i tecnici di fornitori terzi, vedere i Requisiti per certificazioni HV. Ogni volta che si maneggia un raccordo, una barra di distribuzione o un cavo ad alta tensione è necessario indossare idonei dispositivi di protezione individuale (DPI) e guanti isolanti per l'alta tensione con classe di protezione minima 0 (1000 V). Per ulteriori informazioni sulla sicurezza, fare riferimento alle Note tecniche relative ai rischi dell'alta tensione TN-15-92-003, "High Voltage Awareness Care Points"
.
Equipment:
- 1083188-00-B FLUKE DIGITAL MULTIMETER 115
- 1130480-00-A Test Probes, Slim, Fluke TP38
Procedure
- Disconnect 12V/LV power. See 12V/LV Power (Disconnect and Connect).
- Remove the 2nd row lower seat cushion, if not yet removed in the previous step. See Seat Cushion - Lower - 2nd Row (Remove and Replace).
-
Set the multimeter to
measure voltage, and then measure the voltage across the 12V/LV auxiliary
battery terminals.
NoteFor LV (Li-Ion) auxiliary battery: if the voltage across the battery terminals is 0, the battery may have switched off internally. Use a 12V Lead Acid battery for testing. For mobile technicians: use the 12V Lead Acid battery in the Mobile Service vehicle.CAUTIONFor LV (Li-Ion) auxiliary battery: if the voltage across the battery terminals is less than 13 volts or greater than 16 volts, the multimeter is not measuring reliably and must not be used.CAUTIONFor 12V (Lead Acid) auxiliary battery: if the voltage measured is less than 10 volts or greater than 14 volts, the multimeter is not measuring reliably and must not be used.
-
Remove all items from
pockets and ensure not wearing metal items.
-
Inspect HV insulating
gloves.
NoteCheck gloves for damage prior to use, Refer to service document TN-15-92-003 R1, for information on inspecting HV gloves.
-
Put on HV insulating gloves,
leather outer gloves, and safety glasses.
WarningContinue to wear the gloves until instructed to remove them.
- Remove the HV probe cover. See #GUID-E9EF226B-9A39-48A9-B624-FF404018761C.
-
Use a multimeter to probe the
voltages.
WarningIn order to limit potential exposure to high voltage, measure for high voltage in the order specified below.
Measurement Order Component Test
B+
(Probe opening closer to HV DC connector)
B-
(Probe opening, closer to HV Processor Logic connector)
GND
Measured Voltage less than 10 V
Measured Voltage 10 V or more
1 HV battery positive contactor
Positive (+) Lead
Negative (-) Lead on ancillary bay cover
Pass
Fail
2 HV battery negative contactor
Positive (+) Lead
Negative (-) Lead on ancillary bay cover
Pass
Fail
3 HV
Positive (+) Lead
Negative (-) Lead
Pass
Fail
TIpUse of the following tool(s) is recommended:- Electrical Protective Gloves
- Slim Test Probes - 1130480-02-A
- Fluke 1587 - 1076921-00-A
Figure 1. B+ to Ground measurement Figure 2. B- to Ground measurement Figure 3. B+ to B- measurement -
Return to the procedure that
required the vehicle to be electrically isolated.
WarningFollow all safety instructions and PPE requirements of the procedure that required the vehicle to be electrically isolated. Do not remove the HV gloves if the procedure requires you to handle high voltage cables, busbars, or fittings.NoteIf you are no longer exposed to high voltage, the HV insulating gloves may be removed.