Optional: Power Sharing

Power sharing can only be done in a group of six wall connectors (one leader + five followers). Finish commissioning the followers before commissioning the leader. Additionally, make sure that all the followers have a good line of sight to the leader. For more information, see Power Sharing in the applicable "Wall Connector Installation Manual."
  1. Select Power Sharing to connect additional Wall Connectors.
  2. Toggle off Power Sharing to make settings adjustments.
  3. To add a new Wall Connector, select Scan QR Code then scan the Wi-Fi QR code on the new Wall Connector's Quick Start Guide.
  4. Select Add Follower to add the new Wall Connector.
  5. Select Done once the leader is reconnected and the follower has successfully been added.

Program Network Limit

  1. Select Power Sharing Settings to program a network limit.
  2. Enter the appropriate network limit:
    Informational PurposesAn informational icon, calling your attention
    Note
    This is the maximum total current a power sharing network is allowed to consume in amps. This represents the continuous current which the network will not exceed. An electrician will need to determine the correct amount of amperage and confirm that the load center has appropriate overcurrent protection.

Expected Behaviors

  • SSID access point of all Wall Connectors in a power sharing network will continue to broadcast.
  • Removing a Wall Connector from a network will temporarily set that device’s max output to 6 amps. Cycle circuit breaker to reset Wall Connector to original configuration setting.
  • Leader Wall Connector will share site Wi-Fi with follower Wall Connectors.