Pipe - Evaporator - Solenoid Valve to TXV
FRT No: 18032502
Remove
- Evacuate air conditioning refrigerant
(refer to procedure).
- Remove receiver drier
(refer to procedure).
- Clean area around TXV.
- Remove screw securing pipe clamp to TXV (torque - 10 Nm).
- Remove clamp and release pipe.
 | CAUTION: Plug pipe connections to prevent ingress of moisture or dirt. |
- Loosen pipe union to solenoid valve (torque - 18 Nm).
- Remove pipe.
Installation
- Installation procedure reverse of removal except for thr following.
- Replace A/C pipe O-rings.
NOTE: Lubricate new O-ring seals with clean refrigerant oil.