Pipe - Low Pressure - Manifold

FRT No: 18032302

    Remove


  1. Evacuate air conditioning refrigerant (refer to procedure).

  2. Remove compressor (refer to procedure).

  3. Remove nut securing low pressure pipe to compressor (torque - 10 Nm)..

  4. Remove low pressure pipe.

    Installation


  1. Installation procedure reverse of removal except for the following.

  2. Replace A/C pipe O-rings.
  3. NOTE: Lubricate new O-ring seals with clean refrigerant oil.