Pipe - High Pressure - Compressor to Condenser
FRT No: 18032002
Remove
- Remove HVAC assembly
(refer to procedure).
- Loosen the high pressure compressor to condenser pipe at the condenser retaining nut (torque - 25 Nm).
 | CAUTION: To prevent damage always use a suitable wrench to hold backing nut when loosening pipes and unions. |
 | CAUTION: Plug pipe connections to prevent ingress of moisture or dirt. |
- Remove nut securing the high pressure compressor to condenser pipe connection at the compressor (torque - 25 Nm).
 | CAUTION: Plug pipe connections to prevent ingress of moisture or dirt. |
- Remove the high pressure compressor to condenser pipe.
Installation
- Installation procedure is reverse of removal except for the following.
- Replace A/C pipe O-rings.
NOTE: Lubricate new O-ring seals with clean refrigerant oil.