Pipe - Evaporator - Solenoid Valve to TXV
FRT No: 18032502
Remove
- Remove receiver drier
(refer to procedure).
- Remove insulation pad.
-
Loosen union between the low pressure manifold and the manifold to compressor pipe (torque - 35 Nm). Disconnect pipe.
 | CAUTION: To prevent damage always use a suitable wrench to hold backing nut when loosening pipes and unions. |
 | CAUTION: Plug pipe connections to prevent ingress of moisture or dirt. |
-
Loosen union securing the low pressure manifold to the low pressure line (torque - 35 Nm). Disconnect pipe.
-
Remove screw securing the retaining plate to the TXV (torque - 10 Nm).
- Collect the retaining plate. Remove the low pressure manifold to compressor pipe from the TXV.
-
Loosen union securing pipe to solenoid valve (torque - 18 Nm).
- Remove pipe - solenoid valve to evaporator TXV.
Installation
- Installation procedure is reverse of removal except for the following.
- Replace A/C pipe O-rings.