Pipe - Evaporator - Solenoid Valve to TXV

FRT No: 18032502

    Remove


  1. Remove receiver drier (refer to procedure).

  2. Remove insulation pad.

  3. Loosen union between the low pressure manifold and the manifold to compressor pipe (torque - 35 Nm). Disconnect pipe.
  4. CAUTION: To prevent damage always use a suitable wrench to hold backing nut when loosening pipes and unions.
     

    CAUTION: Plug pipe connections to prevent ingress of moisture or dirt.
     


  5. Loosen union securing the low pressure manifold to the low pressure line (torque - 35 Nm). Disconnect pipe.

  6. Remove screw securing the retaining plate to the TXV (torque - 10 Nm).

  7. Collect the retaining plate. Remove the low pressure manifold to compressor pipe from the TXV.

  8. Loosen union securing pipe to solenoid valve (torque - 18 Nm).

  9. Remove pipe - solenoid valve to evaporator TXV.

    Installation


  1. Installation procedure is reverse of removal except for the following.

  2. Replace A/C pipe O-rings.