Pressure Transducer

FRT No: 18032902

    Remove


  1. Remove condenser rear exit duct (refer to procedure).

  2. Recover refrigerant (refer to procedure).

  3. Disconnect transducer harness connector.

  4. Remove pressure transducer (torque - 8 Nm).
  5. CAUTION: To prevent damage always use a suitable wrench to hold backing nut when loosening pipes and unions.
     

    CAUTION: Plug pipe connections to prevent ingress of moisture or dirt.
     

    Installation


  1. Installation procedure reverse of removal.