Device Page Overview

The following pages can be viewed by selecting System, then selecting the desired device from the Devices tab.

Informational PurposesAn informational icon, calling your attention
Note
The Devices tab populates automatically. If a device does not appear, check the communication wiring for errors.

Backup Switch / Backup Gateway 2 Device Page Overview

The Backup Switch / Backup Gateway 2 acts as the Islanding Contactor; this page provides a more direct view of the island state of the system and the state of the micro-grid.

1 Contactor State On Grid / Off Grid
2 Vitals
Grid State:
  • Uncompliant: The grid is not available. Voltage/frequency is out of range for grid code
  • Qualifying: The grid is available, but the system is checking for stability. Can take up to 5 min
  • Compliant: The grid is available
Line voltage 1
Frequency 1

1 When the system is off-grid, the micro-grid (load-side) values are shown as the voltage / frequency can be different on the grid and home side of the island.

Powerwall 3 Device Page Overview

1 Vitals Solar generation, battery charge level, charge/discharge power
2 AC Vitals State, phase and line voltage, frequency
3 Solar DC Inputs DC voltage and current for each active MPPT
4 Battery Battery state, Enable switch status, software version