HV Battery Air Leak Test (Test/Adjust)
Correction code 16102100 FRT 0.66 NOTE: Unless otherwise explicitly stated in the procedure, the correction code and FRT listed above reflect all of the work required to perform this procedure, including the linked procedures. Do not stack correction codes unless explicitly told to do so. NOTE: See Flat Rate Times to learn more about FRTs and how they are created. NOTE: See Personal Protection to make sure you are wearing proper PPE when performing the procedure below. NOTE: See Ergonomic Precautions for safe and healthy working practices.
Warning
Cybertruck electronics are powered by a
48V "mid voltage" or "MV" architecture that is designed to improve efficiency. Servicing
MV components requires extra knowledge and care in order to avoid personal and/or
vehicular harm. Read and understand MV precautions in Electrical Precautions and make sure any required
MV-related training courses have been completed, as applicable.
Warning
Only
technicians who have been trained in High Voltage Awareness and
have completed all required certification courses (if applicable) are permitted to
perform this procedure. Proper personal protective equipment
(PPE) and insulating HV gloves with a minimum rating
of class 0 (1000V) must be worn at all times a high voltage
cable, busbar, or fitting is handled. Refer to Tech Note TN-15-92-003,
High Voltage Awareness Care Pointsfor additional glove and safety information.
Warning
This procedure is a DRAFT.
Although it has been validated, Warnings and Cautions might be missing. Follow safety
requirements and use extreme caution when working on or near High Voltage systems and
components.
Procedure
- Perform Vehicle HV Disablement procedure. See Vehicle HV Disablement Procedure (Test/Adjust).
-
Disconnect RH pressurized pack
line.
Note1x VOSS fitting, 12mm, 8 Nm
-
Install plug onto RH pressurized pack
line.
Note1x plug, Line must be disconnected from pyro fuse access cover
-
Install enclosure leak test adapter
onto open thermal vent.
-
Connect enclosure leak tester onto
adapter.
-
Close both valves on regulator.
-
Connect regulator to air supply.
-
Turn right side regulator valve to
open position.
NoteTurn valve knob to horizontal position.
-
Set regulator to 0.3 psi.
-
Open left side regulator valve to
inject air into platter.
NoteClose right side regulator valve when pressure reaches 0.3 psi and stabilizes, Allow platter to fill for 120 seconds.
- Wait 30 seconds for pressure to settle.
- Record value of starting pressure.
- Wait 30 seconds to test pressure.
-
Record value of end pressure.
NoteSubtract ending pressure from starting pressure, If difference is greater than 0.006 psi then inspect tools and retest, If difference is still greater than 0.006 psi then escalate to Service Engineering, If difference is 0.006 psi or less then proceed with current procedure.
-
Disconnect air supply from
regulator.
-
Disconnect enclosure leak tester from
adapter.
-
Remove enclosure leak test adapter
from open thermal vent.
-
Remove plug from RH pressurized pack
line.
-
Connect RH pressurized pack
line.
Note1x VOSS fitting, 12mm, 8Nm, Remove plug as needed.
-
Remove butyl from remaining thermal
vents.
-
Install a new breather plug onto the
thermal vent.
NotePress the plug evenly.NoteMake sure the tabs are fully engaged and plug is flush with vent.
- Install the rear skid plate. See Skid Plate - Rear (Remove and Install).
- Reconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
- Install the rear underhood apron. See Underhood Apron - Rear (Remove and Install).
- Remove the vehicle from the lift. See Raise Vehicle - 2 Post Lift.
- Raise the LH front window and close the LH front door.