HV Isolation Diagnostics (Standard) (Test)
Correction code
44000134
NOTE: Unless
otherwise explicitly stated in the procedure, the correction code and its
associated FRT reflect all of the work required to perform this procedure,
including the linked procedures. Do not stack correction
codes unless explicitly told to do so.
NOTE: See Flat Rate Times to
learn more about FRTs and how they are created.
NOTE: See Personal Protection to make
sure you are wearing proper PPE when performing the procedure below.
NOTE: See Ergonomic Precautions for safe and healthy
working practices.
High Voltage Awareness Care Pointsfor additional glove and safety information.
- 2026-05-15: Released new procedure.
- Open the LH front door and lower the LH front window.
- Raise and support the vehicle. See Raise Vehicle - 2 Post Lift.
- Connect a laptop with Toolbox to the vehicle. See Toolbox 3 (Connect and Disconnect).
-
Navigate to interactive HV isolation
issues diagnosis
NoteVehicle hub>High voltage>Diagnose HV isolation issues
-
Select "Start interactive
procedure"
-
Read "HV System Global Check Autodiag"
question and select "Yes" to continue
-
Read "HV Awareness" warning and select
"Yes" to continue
-
Select the appropriate vehicle platform
type and then select "Start interactive procedure"
- Open the powered frunk.
- Open the tailgate.
-
Power down vehicle via UI
NoteVerify EPBs are engaged, Select charge port icon to ensure drive state is disengaged then power down vehicle via Controls > Safety > Power Off
- Remove the rear underhood apron. See Underhood Apron - Rear (Remove and Install).
-
Secure MV battery maintainer and support
vehicle
Note1x cover, Secure MV maintainer but leave the Li-ion battery connected, Secure positive terminal to jump post, Secure negative terminal to bolt located between brake fluid reservoir and front trunk, Connect maintainer to power supply, DO NOT allow positive cable to make contact with other metal components, Prevent shorting the cables,Do not have a MV maintainer and the Li-ion battery simultaneously connected for any extended period of time
-
Verify operation of multimeter
NoteSet multimeter to DC voltage, Confirm multimeter is properly measuring voltage by testing MV battery, Touch lightly and do not damage terminals
-
Once the vehicle is in service mode plus
and a MV battery maintainer is connected click next
-
Run the DCA and DI backup routines via
Service mode plus UI then select next
NoteService mode Plus > High voltage > Procedures
-
Confirm vehicle is actively
faulting
NoteService mode plus > High voltage > Hv battery > Clear blocked contactors
-
Observe UI for active HV battery low
isolation alerts
NoteWait up to 5 minutes while observing for active HV battery low isolation alerts then select "Low isolation alert present" if low isolation alerts are present
- Disconnect Toolbox and remove the laptop from the vehicle. See Toolbox 3 (Connect and Disconnect).
- Disconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
-
Remove MV battery maintainer
Note1x cover, Unplug the maintainer first, then remove positive and negative leads from jump posts, Re-secure any jump post covers
-
Raise vehicle fully
NoteSet to a comfortable working height, Lower to locks, Ensure locks engage on both sides to prevent tilting
-
Remove Mid-aero shield
NoteRotate down as far as the battery armor will allow to clear the rear lower control arms, Pull Mid-aero shield out from between battery armor and rear venting bracket, Be careful not to engage any of the breathers during removal
-
Remove all items from pockets and ensure
not wearing metal items
NoteThis includes phones, badges, metal belt buckles airpods and headphones
-
Inspect HV insulating gloves
NoteCheck gloves for damage prior to use, Refer to service document TN-15-92-003, for information on inspecting HV gloves.
-
Put on HV insulating gloves and leather
over gloves
NoteUse HV cut resistant insulated gloves or HV insulating gloves and leather over gloves, HV Insulating gloves must be worn any time a Hioki Tester or Hi-Pot Tester is used, Refer to service document TN-15-92-003 R5 for PPE requirements depending on vehicle configuration
-
Remove clips securing AC compressor HV
harness
Note3x clips
-
Verify no HV - Install amp clamp to RDU
HV harness
NoteVerify meter is zeroed out before performing measurement, Measure single cable. Verify ammeter is installed in correct direction. If current > 0.5A do not proceed with disconnecting HV connector. In this case, start vehicle electrical isolation again to make sure that all was properly shut down. Escalate for assistance as requiredIf current < 0.5A, Ok to disconnect and check voltage at HV plug on the battery side.Release locking tab and rotate the release lever up to disengage the connector, Release harness clip, Do not force the release lever up, Ensure the alignment tabs on the RDU header are not damagedMake sure to wear PPE (HV gloves, safety glasses) when working on high voltage component, Measure B+ to Ground, B- to Ground, B+ to B-, If voltage is greater than 10V, Pack contactors are not open or welded, Stop work and reach out to Service Engineering
-
Select next once vehicle HV disablement
procedure is completed
-
Select rear drive unit
configuration
NoteSelect "single rear drive unit"
-
Disconnect RDU HV harness
Note1x connector, Release locking tab and rotate release lever up, Do not force release lever up, Ensure alignment tabs on header are not damaged
-
Perform isolation test on LH RDU HV
cable at HV battery
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to subframe bolt, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Enter the lowest stable isolation
resistance value recorded in MOhm and then click "next"
-
Read "Heat Pump A/C Compressor + HV
Harness' Isolation Tests" panel and select "Finish Later" to prevent timeout error
-
Release A/C compressor HV harness from
HV battery
Note1x locking connector, 4x clips, Pull down red locking tab and disengage the release lever, Do not force the release lever up, Number of connections may vary by vehicle configuration
-
Perform isolation test on ancillary HV
harness at rear of HV battery
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to subframe bolt, Position leads then press test button, Amber light will turn on, Test all four terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Enter the lowest stable isolation
resistance value recorded in MOhm
NoteSelect "next" to continue
-
Read CP HV Harness FC contactor question
and select "Yes" to continue
-
Read "CP HV Harness Isolation Test"
panel and select "Finish Later" to prevent timeout error
-
Lower vehicle until tires are touching
the ground
NoteRaise lift off locks, then hold lock release lever to keep locks free while vehicle is lowered
- Remove the bed floor. See Bed Floor Assembly (Remove and Install).
-
Remove bolt securing busbar HV connector
lid
Note1x bolt, EP10, 9 Nm
-
Remove bolts securing HV connector to DC
FC header
Note2x bolts, 10mm, 9 Nm
-
Release HV connector from DC FC
header
Note1x connector, Use inflatable airbag if needed to suspend busbar assembly above ancillary assembly
-
Secure CP busbar connector aside
NoteMove connector away from header, Install bags or bungees as needed, Do not open tonneau to prevent damage
-
Perform isolation test on CP HV busbar
connector
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to door striker, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Select "Resume" to continue to "CP HV
Harness Isolation Test" panel
NoteRead panel and submit resistance to continue
-
Read Ancillary certification question
and select "Yes" to continue
-
Read "PCS2 DC Isolation Test" panel and
select "Finish Later" to prevent timeout error
-
Connect HV harness connector to AC compressor
- Install the frunk assembly. See Frunk Assembly (Remove and Install).
- Reconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
- Disconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
-
Raise vehicle fully
NoteSet to a comfortable working height, Lower to locks, Ensure locks engage on both sides to prevent tilting
-
Verify no HV - Install amp clamp to RDU
HV harness
NoteVerify meter is zeroed out before performing measurement, Measure single cable. Verify ammeter is installed in correct direction. If current > 0.5A do not proceed with disconnecting HV connector. In this case, start vehicle electrical isolation again to make sure that all was properly shut down. Escalate for assistance as requiredIf current < 0.5A, Ok to disconnect and check voltage at HV plug on the battery side.Release locking tab and rotate the release lever up to disengage the connector, Release harness clip, Do not force the release lever up, Ensure the alignment tabs on the RDU header are not damagedMake sure to wear PPE (HV gloves, safety glasses) when working on high voltage component, Measure B+ to Ground, B- to Ground, B+ to B-, If voltage is greater than 10V, Pack contactors are not open or welded, Stop work and reach out to Service Engineering
-
Remove pyro fuse access cover
Note4x bolts, E-Torx 5 lobe, 10 Nm
-
Remove primary pyro fuse
Note2x bolts, 13mm, 5 Nm + 60 Degrees, Support pyro fuse while removing bolts
-
Remove secondary pyro fuse
Note2x bolts, 13mm, 5 Nm + 60 Degrees, Support pyro fuse while removing bolts
-
Lower vehicle until tires are touching
the ground
NoteRaise lift off locks, then hold lock release lever to keep locks free while vehicle is lowered
-
Clean all debris from ancillary
cover
NoteDuring removal of ancillary cover any debris on top of the cover may be deposited into the ancillary bay
-
Disconnect ancillary bay MV
connector
Note1x connector, Double locking, Release tab then pivot lever, Release second tab to disengage connector, Wait 1 second between locking tab release to discharge and prevent arcing
-
Support HV Busbar assembly
Note1X Bungee, Suspend assembly to maintain clearance, wrap bungee around busbar assembly to achieve required cord length, Connect bungee to tie down hook on bed side
-
Remove fast charger header doubler
Note2x bolts, E10 5 Lobe Torx, 10 Nm
-
Remove mid voltage header bolts
Note2x bolts, EP10, 6 Nm
-
Release fasteners securing ancillary
cover to HV battery
Note22x bolts, E10 5-Lobe, 6 Nm, Use E10 5-Lobe socket without magnet, The fasteners are captive and will stay attached to the penthouse cover, Follow fastening order
-
Remove ancillary cover
NoteInstall vacuum cup to ancillary cover surface, Lift and maneuver cover around busbar and tonneau cage to remove
-
Disconnect device cluster HV DC harness
from PCS
Note1x connector, Release locking tab, Gently pull up
-
Perform isolation test on PCS2 DC
connector at ancillary
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to HV battery chassis bolt, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Enter the lowest stable isolation
resistance value recorded in MOhm
NoteSelect "next " to continue
-
Read "ACJB Isolation Test" panel and
select "Finish Later" to prevent timeout error
-
Release ancillary bay MV connector
header
Note4x tabs, Move aside as needed
-
Disconnect HVC logic connector
Note1x connector
-
Disconnect negative pack contactor sense
connectors
Note2x connectors
-
Disconnect positive pack contactor sense
connectors
Note2x connectors
-
Disconnect ACJB HV connector
Note1x connector, Release locking tab, Gently pull up
-
Perform isolation test on ACJB HV
connector
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to HV battery chassis bolt, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Select "Resume" to continue to "ACJB
Isolation Test" panel
NoteRead panel and submit resistance to continue
-
Read "External Side DC Link Isolation
Test" panel and select "Finish Later" to prevent timeout error
-
Perform isolation test on external side
of negative and positive pack contactors
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to HV battery chassis bolt, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Select "Resume" to continue to "External
Side DC Link Isolation Test" panel
NoteRead panel and submit resistance to continue
-
Read "Internal Side DC Link Isolation
Test" panel and select "Finish Later" to prevent timeout error
-
Perform isolation test on internal side
of negative and positive pack contactors and pyro disconnect
NoteSet insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to HV battery chassis bolt, Position leads then press test button, Amber light will turn on, Test all four terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Select "Resume" to continue to "Internal
Side DC Link Isolation Test" panel
NoteRead panel and submit resistance to continue
-
Read "Warm Heat Pump A/C Compressor
Isolation Test" panel and select "Finish Later" to prevent timeout error
-
Connect ACJB HV connector
Note1x connector, Secure locking tab
-
Connect positive pack contactor sense
connectors
Note2x connectors
-
Connect negative pack contactor sense
connectors
Note2x connectors
-
Connect HVC logic connector
Note1x connector
-
Secure ancillary bay MV connector
header
Note4x tabs
-
Connect device cluster HV DC harness to
PCS
Note1x connector, Secure locking tab
-
Install ancillary cover
NoteUse suction cup and maneuver around busbar and tonneau cage
-
Secure ancillary cover fasteners to HV
battery
Note22x bolts, E10 5-Lobe, 6 Nm, Use E10 5-Lobe socket without magnet, The fasteners are captive and will stay attached to the penthouse cover, Follow fastening order
-
Install mid voltage header bolts
Note2x bolts, EP10, 6 Nm
-
Install fast charger header
doubler
Note2x bolts, E10 5 Lobe Torx, 10Nm
-
Clean HV connector contact surface of
residual Penetrox
NoteAllow 1 minute dry time after removing Penetrox, New busbar comes with Penetrox applied to HV connector
-
Clean busbar HV connector contact
surface of residual Penetrox
NoteAllow 1 minute dry time after removing Penetrox, It is necessary to clean HV connector during re-use of busbar
-
Apply Penetrox onto HV connector
joints
NoteApply 2 drops of Penetrox A-13 about 5mm in diameter to either side of the hole on both leads, Spread evenly to verify the contact surface is fully covered
-
Position busbar connector and lower onto
HV header
NoteRelease bungee cord
-
Install bolts securing charge port
busbar kit to HV Header
Note2x bolts, 10mm, 9 Nm
-
Perform Hioki resistance test at each HV
joint from HV busbar lead to bolt head
Note2x HV joints, When using Hioki tester, verify the meter has been properly adjusted and set prior to usageThe acceptable resistance is between 0.050 mΩ (50 μΩ) and 0.195 mΩ (195 μΩ).If the resistance is greater than 0.195 mΩ (195 μΩ), stop work and escalate the Toolbox session.If the resistance is lower than 0.050 mΩ (50 μΩ), reposition the probes and measure again.If the resistance is repeatedly between 0.00 mΩ and 0.050 mΩ (50 μΩ), hioki test passed, proceed to next step
-
Install bolt securing busbar HV
connector lid
Note1x bolt, EP10, 9 Nm
-
Connect ancillary bay MV connector
Note1x connector, double locking, Rotate lever into 2nd lock, Perform a pull test to ensure connector engaged correctly
-
Raise vehicle fully
NoteSet to a comfortable working height, Lower to locks, Ensure locks engage on both sides to prevent tilting
-
Clean pyro fuse mating surfaces
NoteUsing an insulated tool wipe all four busbar mating surfaces within pyro fuse bay, Wipe top and bottom mating surfaces of each pyro fuse, Ensure no debris is present on any mating surface, Process shown with device cluster removed for clarity and safety, HV gloves and associated PPE must be worn at all times when cleaning mating surfaces, Allow 1 minute for IPA to dry
-
Install secondary pyro fuse
Note2x bolts, 13mm, 5 Nm + 60 degrees, Support pyro fuse while installing bolts, Bolts may be reused
-
Install primary pyro fuse
Note2x bolts, 13mm, 5 Nm + 60 degrees, Support pyro fuse while installing bolts, Bolts may be reused
-
Perform Hioki resistance test at each HV
joint from HV busbar lead to pyro fuse busbar
Note4x HV joints, When using Hioki tester, verify the meter has been properly adjusted and set prior to usageThe acceptable resistance is between 0.050 mΩ (50 μΩ) and 0.195 mΩ (195 μΩ).If the resistance is greater than 0.195 mΩ (195 μΩ), stop work and escalate the Toolbox session.If the resistance is lower than 0.050 mΩ (50 μΩ), reposition the probes and measure again.If the resistance is repeatedly between 0.00 mΩ and 0.050 mΩ (50 μΩ), hioki test passed, proceed to next step
- Remove HV insulating gloves
-
Install pyro fuse access cover with
airlines attached
Note4x bolts, E-Torx 5 lobe, 10 Nm, Ensure seal is fully seated and undamaged, Secure 2 airline mounting clips to HV Battery, If HV pack is being shipped then pyro fuses must be removed
-
Secure A/C compressor HV harness onto
battery
Note1x locking connector, 4x clips, Engage locking tab, Do not force lever up, Number of connections may vary by vehicle configuration
-
Connect RDU HV harness
Note1x connector, Verify lever is upright and in open position, Carefully seat connector and allow lever to engage, Fully secure lever and verify red tab is locked, Do not damage any pins
-
Connect LHS RDU HV harness
Note1x connector, Verify lever is upright and in open position, Carefully seat connector and allow lever to engage, Fully secure lever and verify red tab is locked, Do not damage any pins
-
Install clips securing AC compressor HV
harness
Note3x clips
- Install rear skid plate. See Skid Plate - Rear (Remove and Install).
-
Lower vehicle until tires are touching
the ground
NoteRaise lift off locks, then hold lock release lever to keep locks free while vehicle is lowered
- Reconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
- Remove the frunk assembly. See Frunk Assembly (Remove and Install)
-
Warm up AC compressor via UI
NoteVia Climate Control > ON, Set fan speed to 10, Set temperature to HI or LO, Allow 20 minute run time
-
Turn off the AC and blower motor
- Disconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
-
Disconnect HV harness connector from AC
compressor
Note1x locking electrical connector, Pull red locking tab away from compressor then slide black lock upwards to release
-
Perform isolation test on AC
compressor
NoteMove HV harness aside as needed, Set insulation meter to 1000V and red lead to resistance (Ω), Secure black alligator clip to shock tower brace, Position leads then press test button, Amber light will turn on, Test both terminals, Make sure to wear proper PPE, Verify voltage drops below 10V after releasing test button
-
Select "Resume" to continue to "Warm
Heat Pump A/C Compressor Isolation Test" panel
NoteRead panel and submit resistance to continue
-
Read "HV Isolation Diagnostic Debug"
results
NoteIf this panel is reached then screenshot and escalate a Toolbox session, Select "X" at top right of window to close once complete
- Reconnect MV power. See Mid-Voltage Power (Disconnect and Connect) (Modify).
- Install the rear underhood apron. See Underhood Apron - Rear (Remove and Install).
- Install the bed floor assembly. See Bed Floor Assembly (Remove and Install).
- Exit Service Mode. See Service Mode.
- Remove the vehicle from the lift. See Raise Vehicle - 2 Post Lift.
- Raise the LH front window and close the LH front door.